Documentation enhancements to improve documentation cross-references.
This commit is contained in:
parent
6865a7bc09
commit
9cec85bfd9
22 changed files with 425 additions and 241 deletions
|
@ -69,24 +69,24 @@
|
|||
|
||||
/* Public Interface - May be used in end-application: */
|
||||
/* Macros: */
|
||||
/** Endpoint data direction mask for Endpoint_ConfigureEndpoint(). This indicates that the endpoint
|
||||
/** Endpoint data direction mask for \ref Endpoint_ConfigureEndpoint(). This indicates that the endpoint
|
||||
* should be initialized in the OUT direction - i.e. data flows from host to device.
|
||||
*/
|
||||
#define ENDPOINT_DIR_OUT (0 << EPDIR)
|
||||
|
||||
/** Endpoint data direction mask for Endpoint_ConfigureEndpoint(). This indicates that the endpoint
|
||||
/** Endpoint data direction mask for \ref Endpoint_ConfigureEndpoint(). This indicates that the endpoint
|
||||
* should be initialized in the IN direction - i.e. data flows from device to host.
|
||||
*/
|
||||
#define ENDPOINT_DIR_IN (1 << EPDIR)
|
||||
|
||||
/** Mask for the bank mode selection for the Endpoint_ConfigureEndpoint() macro. This indicates
|
||||
/** Mask for the bank mode selection for the \ref Endpoint_ConfigureEndpoint() macro. This indicates
|
||||
* that the endpoint should have one single bank, which requires less USB FIFO memory but results
|
||||
* in slower transfers as only one USB device (the AVR or the host) can access the endpoint's
|
||||
* bank at the one time.
|
||||
*/
|
||||
#define ENDPOINT_BANK_SINGLE (0 << EPBK0)
|
||||
|
||||
/** Mask for the bank mode selection for the Endpoint_ConfigureEndpoint() macro. This indicates
|
||||
/** Mask for the bank mode selection for the \ref Endpoint_ConfigureEndpoint() macro. This indicates
|
||||
* that the endpoint should have two banks, which requires more USB FIFO memory but results
|
||||
* in faster transfers as one USB device (the AVR or the host) can access one bank while the other
|
||||
* accesses the second bank.
|
||||
|
@ -146,7 +146,7 @@
|
|||
* \note This interrupt must be enabled and cleared on *each* endpoint which requires it (after the
|
||||
* endpoint is selected), and will fire the common endpoint interrupt vector.
|
||||
*
|
||||
* \see ENDPOINT_PIPE_vect for more information on the common pipe and endpoint interrupt vector.
|
||||
* \see \ref ENDPOINT_PIPE_vect for more information on the common pipe and endpoint interrupt vector.
|
||||
*/
|
||||
#define ENDPOINT_INT_SETUP UEIENX, (1 << RXSTPE), UEINTX, (1 << RXSTPI)
|
||||
|
||||
|
@ -160,7 +160,7 @@
|
|||
* \note This interrupt must be enabled and cleared on *each* endpoint which requires it (after the
|
||||
* endpoint is selected), and will fire the common endpoint interrupt vector.
|
||||
*
|
||||
* \see ENDPOINT_PIPE_vect for more information on the common pipe and endpoint interrupt vector.
|
||||
* \see \ref ENDPOINT_PIPE_vect for more information on the common pipe and endpoint interrupt vector.
|
||||
*/
|
||||
#define ENDPOINT_INT_IN UEIENX, (1 << TXINE) , UEINTX, (1 << TXINI)
|
||||
|
||||
|
@ -174,7 +174,7 @@
|
|||
* \note This interrupt must be enabled and cleared on *each* endpoint which requires it (after the
|
||||
* endpoint is selected), and will fire the common endpoint interrupt vector.
|
||||
*
|
||||
* \see ENDPOINT_PIPE_vect for more information on the common pipe and endpoint interrupt vector.
|
||||
* \see \ref ENDPOINT_PIPE_vect for more information on the common pipe and endpoint interrupt vector.
|
||||
*/
|
||||
#define ENDPOINT_INT_OUT UEIENX, (1 << RXOUTE), UEINTX, (1 << RXOUTI)
|
||||
|
||||
|
@ -200,7 +200,7 @@
|
|||
static inline uint8_t Endpoint_GetCurrentEndpoint(void);
|
||||
|
||||
/** Selects the given endpoint number. If the address from the device descriptors is used, the
|
||||
* value should be masked with the ENDPOINT_EPNUM_MASK constant to extract only the endpoint
|
||||
* value should be masked with the \ref ENDPOINT_EPNUM_MASK constant to extract only the endpoint
|
||||
* number (and discarding the endpoint direction bit).
|
||||
*
|
||||
* Any endpoint operations which do not require the endpoint number to be indicated will operate on
|
||||
|
@ -220,8 +220,7 @@
|
|||
/** Enables the currently selected endpoint so that data can be sent and received through it to
|
||||
* and from a host.
|
||||
*
|
||||
* \note Endpoints must first be configured properly rather than just being enabled via the
|
||||
* Endpoint_ConfigureEndpoint() macro, which calls Endpoint_EnableEndpoint() automatically.
|
||||
* \note Endpoints must first be configured properly via \ref Endpoint_ConfigureEndpoint().
|
||||
*/
|
||||
static inline void Endpoint_EnableEndpoint(void);
|
||||
|
||||
|
@ -330,7 +329,7 @@
|
|||
* way for devices to indicate invalid commands to the host so that the current transfer can be
|
||||
* aborted and the host can begin its own recovery sequence.
|
||||
*
|
||||
* The currently selected endpoint remains stalled until either the Endpoint_ClearStall() macro
|
||||
* The currently selected endpoint remains stalled until either the \ref Endpoint_ClearStall() macro
|
||||
* is called, or the host issues a CLEAR FEATURE request to the device for the currently selected
|
||||
* endpoint.
|
||||
*
|
||||
|
@ -415,7 +414,7 @@
|
|||
#endif
|
||||
|
||||
/* Enums: */
|
||||
/** Enum for the possible error return codes of the Endpoint_WaitUntilReady function.
|
||||
/** Enum for the possible error return codes of the \ref Endpoint_WaitUntilReady() function.
|
||||
*
|
||||
* \ingroup Group_EndpointRW
|
||||
*/
|
||||
|
@ -430,7 +429,7 @@
|
|||
*/
|
||||
ENDPOINT_READYWAIT_Timeout = 3, /**< The host failed to accept or send the next packet
|
||||
* within the software timeout period set by the
|
||||
* USB_STREAM_TIMEOUT_MS macro.
|
||||
* \ref USB_STREAM_TIMEOUT_MS macro.
|
||||
*/
|
||||
};
|
||||
|
||||
|
@ -449,7 +448,7 @@
|
|||
*/
|
||||
ENDPOINT_RWSTREAM_ERROR_Timeout = 2, /**< The host failed to accept or send the next packet
|
||||
* within the software timeout period set by the
|
||||
* USB_STREAM_TIMEOUT_MS macro.
|
||||
* \ref USB_STREAM_TIMEOUT_MS macro.
|
||||
*/
|
||||
ENDPOINT_RWSTREAM_ERROR_CallbackAborted = 3, /**< Indicates that the stream's callback function
|
||||
* aborted the transfer early.
|
||||
|
@ -703,15 +702,15 @@
|
|||
* device (i.e. endpoint 1 should be configured before endpoint 2 and so on).
|
||||
*
|
||||
* The endpoint type may be one of the EP_TYPE_* macros listed in LowLevel.h and the direction
|
||||
* may be either ENDPOINT_DIR_OUT or ENDPOINT_DIR_IN.
|
||||
* may be either \ref ENDPOINT_DIR_OUT or \ref ENDPOINT_DIR_IN.
|
||||
*
|
||||
* The bank size must indicate the maximum packet size that the endpoint can handle. Different
|
||||
* endpoint numbers can handle different maximum packet sizes - refer to the chosen USB AVR's
|
||||
* datasheet to determine the maximum bank size for each endpoint.
|
||||
*
|
||||
* The banking mode may be either ENDPOINT_BANK_SINGLE or ENDPOINT_BANK_DOUBLE.
|
||||
* The banking mode may be either \ref ENDPOINT_BANK_SINGLE or \ref ENDPOINT_BANK_DOUBLE.
|
||||
*
|
||||
* The success of this routine can be determined via the Endpoint_IsConfigured() macro.
|
||||
* The success of this routine can be determined via the \ref Endpoint_IsConfigured() macro.
|
||||
*
|
||||
* By default, the routine is entirely dynamic, and will accept both constant and variable inputs.
|
||||
* If dynamic configuration is unused, a small space savings can be made by defining the
|
||||
|
@ -733,18 +732,18 @@
|
|||
*
|
||||
* \ingroup Group_EndpointRW
|
||||
*
|
||||
* \return A value from the Endpoint_WaitUntilReady_ErrorCodes_t enum.
|
||||
* \return A value from the \ref Endpoint_WaitUntilReady_ErrorCodes_t enum.
|
||||
*/
|
||||
uint8_t Endpoint_WaitUntilReady(void);
|
||||
|
||||
/** Reads and discards the given number of bytes from the endpoint from the given buffer,
|
||||
* discarding fully read packets from the host as needed. The last packet is not automatically
|
||||
* discarded once the remaining bytes has been read; the user is responsible for manually
|
||||
* discarding the last packet from the host via the Endpoint_ClearOUT() macro. Between
|
||||
* discarding the last packet from the host via the \ref Endpoint_ClearOUT() macro. Between
|
||||
* each USB packet, the given stream callback function is executed repeatedly until the next
|
||||
* packet is ready, allowing for early aborts of stream transfers.
|
||||
*
|
||||
* The callback routine should be created using the STREAM_CALLBACK() macro. If the token
|
||||
* The callback routine should be created using the \ref STREAM_CALLBACK() macro. If the token
|
||||
* NO_STREAM_CALLBACKS is passed via the -D option to the compiler, stream callbacks are disabled
|
||||
* and this function has the Callback parameter omitted.
|
||||
*
|
||||
|
@ -755,7 +754,7 @@
|
|||
* \param Length Number of bytes to send via the currently selected endpoint.
|
||||
* \param Callback Name of a callback routine to call between successive USB packet transfers, NULL if no callback
|
||||
*
|
||||
* \return A value from the Endpoint_Stream_RW_ErrorCodes_t enum.
|
||||
* \return A value from the \ref Endpoint_Stream_RW_ErrorCodes_t enum.
|
||||
*/
|
||||
uint8_t Endpoint_Discard_Stream(uint16_t Length
|
||||
#if !defined(NO_STREAM_CALLBACKS) || defined(__DOXYGEN__)
|
||||
|
@ -766,11 +765,11 @@
|
|||
/** Writes the given number of bytes to the endpoint from the given buffer in little endian,
|
||||
* sending full packets to the host as needed. The last packet filled is not automatically sent;
|
||||
* the user is responsible for manually sending the last written packet to the host via the
|
||||
* Endpoint_ClearIN() macro. Between each USB packet, the given stream callback function
|
||||
* \ref Endpoint_ClearIN() macro. Between each USB packet, the given stream callback function
|
||||
* is executed repeatedly until the endpoint is ready to accept the next packet, allowing for early
|
||||
* aborts of stream transfers.
|
||||
*
|
||||
* The callback routine should be created using the STREAM_CALLBACK() macro. If the token
|
||||
* The callback routine should be created using the \ref STREAM_CALLBACK() macro. If the token
|
||||
* NO_STREAM_CALLBACKS is passed via the -D option to the compiler, stream callbacks are disabled
|
||||
* and this function has the Callback parameter omitted.
|
||||
*
|
||||
|
@ -782,7 +781,7 @@
|
|||
* \param Length Number of bytes to read for the currently selected endpoint into the buffer.
|
||||
* \param Callback Name of a callback routine to call between successive USB packet transfers, NULL if no callback
|
||||
*
|
||||
* \return A value from the Endpoint_Stream_RW_ErrorCodes_t enum.
|
||||
* \return A value from the \ref Endpoint_Stream_RW_ErrorCodes_t enum.
|
||||
*/
|
||||
uint8_t Endpoint_Write_Stream_LE(const void* Buffer, uint16_t Length
|
||||
#if !defined(NO_STREAM_CALLBACKS) || defined(__DOXYGEN__)
|
||||
|
@ -793,11 +792,11 @@
|
|||
/** Writes the given number of bytes to the endpoint from the given buffer in big endian,
|
||||
* sending full packets to the host as needed. The last packet filled is not automatically sent;
|
||||
* the user is responsible for manually sending the last written packet to the host via the
|
||||
* Endpoint_ClearIN() macro. Between each USB packet, the given stream callback function
|
||||
* \ref Endpoint_ClearIN() macro. Between each USB packet, the given stream callback function
|
||||
* is executed repeatedly until the endpoint is ready to accept the next packet, allowing for early
|
||||
* aborts of stream transfers.
|
||||
*
|
||||
* The callback routine should be created using the STREAM_CALLBACK() macro. If the token
|
||||
* The callback routine should be created using the \ref STREAM_CALLBACK() macro. If the token
|
||||
* NO_STREAM_CALLBACKS is passed via the -D option to the compiler, stream callbacks are disabled
|
||||
* and this function has the Callback parameter omitted.
|
||||
*
|
||||
|
@ -809,7 +808,7 @@
|
|||
* \param Length Number of bytes to read for the currently selected endpoint into the buffer.
|
||||
* \param Callback Name of a callback routine to call between successive USB packet transfers, NULL if no callback
|
||||
*
|
||||
* \return A value from the Endpoint_Stream_RW_ErrorCodes_t enum.
|
||||
* \return A value from the \ref Endpoint_Stream_RW_ErrorCodes_t enum.
|
||||
*/
|
||||
uint8_t Endpoint_Write_Stream_BE(const void* Buffer, uint16_t Length
|
||||
#if !defined(NO_STREAM_CALLBACKS) || defined(__DOXYGEN__)
|
||||
|
@ -820,11 +819,11 @@
|
|||
/** Reads the given number of bytes from the endpoint from the given buffer in little endian,
|
||||
* discarding fully read packets from the host as needed. The last packet is not automatically
|
||||
* discarded once the remaining bytes has been read; the user is responsible for manually
|
||||
* discarding the last packet from the host via the Endpoint_ClearOUT() macro. Between
|
||||
* discarding the last packet from the host via the \ref Endpoint_ClearOUT() macro. Between
|
||||
* each USB packet, the given stream callback function is executed repeatedly until the endpoint
|
||||
* is ready to accept the next packet, allowing for early aborts of stream transfers.
|
||||
*
|
||||
* The callback routine should be created using the STREAM_CALLBACK() macro. If the token
|
||||
* The callback routine should be created using the \ref STREAM_CALLBACK() macro. If the token
|
||||
* NO_STREAM_CALLBACKS is passed via the -D option to the compiler, stream callbacks are disabled
|
||||
* and this function has the Callback parameter omitted.
|
||||
*
|
||||
|
@ -836,7 +835,7 @@
|
|||
* \param Length Number of bytes to send via the currently selected endpoint.
|
||||
* \param Callback Name of a callback routine to call between successive USB packet transfers, NULL if no callback
|
||||
*
|
||||
* \return A value from the Endpoint_Stream_RW_ErrorCodes_t enum.
|
||||
* \return A value from the \ref Endpoint_Stream_RW_ErrorCodes_t enum.
|
||||
*/
|
||||
uint8_t Endpoint_Read_Stream_LE(void* Buffer, uint16_t Length
|
||||
#if !defined(NO_STREAM_CALLBACKS) || defined(__DOXYGEN__)
|
||||
|
@ -847,11 +846,11 @@
|
|||
/** Reads the given number of bytes from the endpoint from the given buffer in big endian,
|
||||
* discarding fully read packets from the host as needed. The last packet is not automatically
|
||||
* discarded once the remaining bytes has been read; the user is responsible for manually
|
||||
* discarding the last packet from the host via the Endpoint_ClearOUT() macro. Between
|
||||
* discarding the last packet from the host via the \ref Endpoint_ClearOUT() macro. Between
|
||||
* each USB packet, the given stream callback function is executed repeatedly until the endpoint
|
||||
* is ready to accept the next packet, allowing for early aborts of stream transfers.
|
||||
*
|
||||
* The callback routine should be created using the STREAM_CALLBACK() macro. If the token
|
||||
* The callback routine should be created using the \ref STREAM_CALLBACK() macro. If the token
|
||||
* NO_STREAM_CALLBACKS is passed via the -D option to the compiler, stream callbacks are disabled
|
||||
* and this function has the Callback parameter omitted.
|
||||
*
|
||||
|
@ -863,7 +862,7 @@
|
|||
* \param Length Number of bytes to send via the currently selected endpoint.
|
||||
* \param Callback Name of a callback routine to call between successive USB packet transfers, NULL if no callback
|
||||
*
|
||||
* \return A value from the Endpoint_Stream_RW_ErrorCodes_t enum.
|
||||
* \return A value from the \ref Endpoint_Stream_RW_ErrorCodes_t enum.
|
||||
*/
|
||||
uint8_t Endpoint_Read_Stream_BE(void* Buffer, uint16_t Length
|
||||
#if !defined(NO_STREAM_CALLBACKS) || defined(__DOXYGEN__)
|
||||
|
@ -874,7 +873,7 @@
|
|||
/** Writes the given number of bytes to the CONTROL type endpoint from the given buffer in little endian,
|
||||
* sending full packets to the host as needed. The host OUT acknowledgement is not automatically cleared
|
||||
* in both failure and success states; the user is responsible for manually clearing the setup OUT to
|
||||
* finalize the transfer via the Endpoint_ClearOUT() macro.
|
||||
* finalize the transfer via the \ref Endpoint_ClearOUT() macro.
|
||||
*
|
||||
* \note This routine should only be used on CONTROL type endpoints.
|
||||
*
|
||||
|
@ -886,14 +885,14 @@
|
|||
* \param Buffer Pointer to the source data buffer to read from.
|
||||
* \param Length Number of bytes to read for the currently selected endpoint into the buffer.
|
||||
*
|
||||
* \return A value from the Endpoint_ControlStream_RW_ErrorCodes_t enum.
|
||||
* \return A value from the \ref Endpoint_ControlStream_RW_ErrorCodes_t enum.
|
||||
*/
|
||||
uint8_t Endpoint_Write_Control_Stream_LE(const void* Buffer, uint16_t Length) ATTR_NON_NULL_PTR_ARG(1);
|
||||
|
||||
/** Writes the given number of bytes to the CONTROL type endpoint from the given buffer in big endian,
|
||||
* sending full packets to the host as needed. The host OUT acknowledgement is not automatically cleared
|
||||
* in both failure and success states; the user is responsible for manually clearing the setup OUT to
|
||||
* finalize the transfer via the Endpoint_ClearOUT() macro.
|
||||
* finalize the transfer via the \ref Endpoint_ClearOUT() macro.
|
||||
*
|
||||
* \note This routine should only be used on CONTROL type endpoints.
|
||||
*
|
||||
|
@ -905,14 +904,14 @@
|
|||
* \param Buffer Pointer to the source data buffer to read from.
|
||||
* \param Length Number of bytes to read for the currently selected endpoint into the buffer.
|
||||
*
|
||||
* \return A value from the Endpoint_ControlStream_RW_ErrorCodes_t enum.
|
||||
* \return A value from the \ref Endpoint_ControlStream_RW_ErrorCodes_t enum.
|
||||
*/
|
||||
uint8_t Endpoint_Write_Control_Stream_BE(const void* Buffer, uint16_t Length) ATTR_NON_NULL_PTR_ARG(1);
|
||||
|
||||
/** Reads the given number of bytes from the CONTROL endpoint from the given buffer in little endian,
|
||||
* discarding fully read packets from the host as needed. The device IN acknowledgement is not
|
||||
* automatically sent after success or failure states; the user is responsible for manually sending the
|
||||
* setup IN to finalize the transfer via the Endpoint_ClearIN() macro.
|
||||
* setup IN to finalize the transfer via the \ref Endpoint_ClearIN() macro.
|
||||
*
|
||||
* \note This routine should only be used on CONTROL type endpoints.
|
||||
*
|
||||
|
@ -924,14 +923,14 @@
|
|||
* \param Buffer Pointer to the destination data buffer to write to.
|
||||
* \param Length Number of bytes to send via the currently selected endpoint.
|
||||
*
|
||||
* \return A value from the Endpoint_ControlStream_RW_ErrorCodes_t enum.
|
||||
* \return A value from the \ref Endpoint_ControlStream_RW_ErrorCodes_t enum.
|
||||
*/
|
||||
uint8_t Endpoint_Read_Control_Stream_LE(void* Buffer, uint16_t Length) ATTR_NON_NULL_PTR_ARG(1);
|
||||
|
||||
/** Reads the given number of bytes from the CONTROL endpoint from the given buffer in big endian,
|
||||
* discarding fully read packets from the host as needed. The device IN acknowledgement is not
|
||||
* automatically sent after success or failure states; the user is responsible for manually sending the
|
||||
* setup IN to finalize the transfer via the Endpoint_ClearIN() macro.
|
||||
* setup IN to finalize the transfer via the \ref Endpoint_ClearIN() macro.
|
||||
*
|
||||
* \note This routine should only be used on CONTROL type endpoints.
|
||||
*
|
||||
|
@ -943,7 +942,7 @@
|
|||
* \param Buffer Pointer to the destination data buffer to write to.
|
||||
* \param Length Number of bytes to send via the currently selected endpoint.
|
||||
*
|
||||
* \return A value from the Endpoint_ControlStream_RW_ErrorCodes_t enum.
|
||||
* \return A value from the \ref Endpoint_ControlStream_RW_ErrorCodes_t enum.
|
||||
*/
|
||||
uint8_t Endpoint_Read_Control_Stream_BE(void* Buffer, uint16_t Length) ATTR_NON_NULL_PTR_ARG(1);
|
||||
|
||||
|
|
Loading…
Add table
Add a link
Reference in a new issue