Add support for complementary outputs to the WS2812 PWM driver (#11988)
This commit is contained in:
		
							parent
							
								
									8f5d2e546e
								
							
						
					
					
						commit
						18a333ec6b
					
				
					 2 changed files with 13 additions and 1 deletions
				
			
		| 
						 | 
				
			
			@ -102,11 +102,14 @@ Configure the hardware via your config.h:
 | 
			
		|||
#define WS2812_PWM_DRIVER PWMD2  // default: PWMD2
 | 
			
		||||
#define WS2812_PWM_CHANNEL 2  // default: 2
 | 
			
		||||
#define WS2812_PWM_PAL_MODE 2  // Pin "alternate function", see the respective datasheet for the appropriate values for your MCU. default: 2
 | 
			
		||||
//#define WS2812_PWM_COMPLEMENTARY_OUTPUT // Define for a complementary timer output (TIMx_CHyN); omit for a normal timer output (TIMx_CHy).
 | 
			
		||||
#define WS2812_DMA_STREAM STM32_DMA1_STREAM2  // DMA Stream for TIMx_UP, see the respective reference manual for the appropriate values for your MCU.
 | 
			
		||||
#define WS2812_DMA_CHANNEL 2  // DMA Channel for TIMx_UP, see the respective reference manual for the appropriate values for your MCU.
 | 
			
		||||
#define WS2812_DMAMUX_ID STM32_DMAMUX1_TIM2_UP // DMAMUX configuration for TIMx_UP -- only required if your MCU has a DMAMUX peripheral, see the respective reference manual for the appropriate values for your MCU.
 | 
			
		||||
```
 | 
			
		||||
 | 
			
		||||
Note that using a complementary timer output (TIMx_CHyN) is possible only for advanced-control timers (TIM1, TIM8, TIM20 on STM32), and the `STM32_PWM_USE_ADVANCED` option in mcuconf.h must be set to `TRUE`.  Complementary outputs of general-purpose timers are not supported due to ChibiOS limitations.
 | 
			
		||||
 | 
			
		||||
You must also turn on the PWM feature in your halconf.h and mcuconf.h
 | 
			
		||||
 | 
			
		||||